1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

Alternator Change

Discussion in 'Intermediate CJ-5/6/7/8' started by Chilly, Apr 22, 2019.

  1. May 20, 2019
    Chilly

    Chilly Active Member

    Joined:
    Mar 12, 2007
    Messages:
    1,486
    Tim, guess what I received from Powermaster as replacement for Motorola Jeep alternator? A milled 12SI 100A one-wire!
    1558399548883-324594203.jpg

    1558399588899-375553803.jpg
     
  2. May 20, 2019
    timgr

    timgr We stand on the shoulders of giants. 2022 Sponsor

    Medford Mass USA
    Joined:
    Aug 10, 2003
    Messages:
    23,596
    Woohoo!

    You have no ammeter, I presume?
     
  3. May 20, 2019
    Chilly

    Chilly Active Member

    Joined:
    Mar 12, 2007
    Messages:
    1,486
    Had, but already have a voltmeter and new harness kit. And yes, I'll use a monster wire between alternator and battery
     
  4. May 21, 2019
    johneyboy03

    johneyboy03 The green beast

    Quebec, Canada
    Joined:
    Jan 15, 2011
    Messages:
    2,116
    96 amp at idle it will bring a lot of amp.

    Only worry i would have will be belt slipping. The bigger in amp the alternator is the more power you will need to make it turn. When i put my cs144 (almost same spec as you) i have to use a dual belt set-up to get rid of the slippage.
     
  5. May 21, 2019
    Chilly

    Chilly Active Member

    Joined:
    Mar 12, 2007
    Messages:
    1,486
    That is true, but only when there is sufficient load. Under normal conditions a 100A alternator is no more difficult to spin than a 55A alternator. From 56A on up it is indeed harder to spin. Now there may be a slight difference just because its spinning more copper, but that's not the same.

    Powermaster instructions are to tighten until you can move the engine by turning the alternator shaft with a socket. That's a pretty snug belt.
     
  6. May 21, 2019
    mike starck

    mike starck Member

    salem,oregon
    Joined:
    Jun 22, 2006
    Messages:
    762
    I run a ford 3g 135 amp one wire on my pickup(1966 w/FE eng) with a single v-belt.Borderline acceptable but with a little larger diameter pulley it is working fine. Can't manage dual belts with the present setup and serpentine is more than I want to spend after investing in the present setup. mike
     
  7. May 21, 2019
    45es

    45es Active Member 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Naches, WA
    Joined:
    Mar 31, 2007
    Messages:
    1,106
    I'd keep a watch on the water pump. A belt that tight can wear out water pump bearing pretty fast.
     
New Posts