1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

Emergency / Turn Signal Flasher Module Help

Discussion in 'Early CJ5 and CJ6 Tech' started by Jonbbrew, Nov 18, 2020.

  1. Nov 18, 2020
    Jonbbrew

    Jonbbrew Member

    Paso Robles, CA
    Joined:
    Mar 14, 2015
    Messages:
    739
    Hello all,

    As part of my re-wiring of the jeep and adding some gauges and turn signal indicators, i am thinking of replacing my 2 prong flashers with 3 prongs so i can just attach the signal indicators directly to the flasher module. In doing a quick research i am wondering how the best way to pick which one to use thus amp rating?

    So the turn flasher will need to handle front and back lamps on either side plus one small indicator lamp on dash. Do i just look up the amperage for 2 lights and the indicator and add them together since only one side will be on at a time? I assume it wont be much.

    The hazard would have to be a little larger as it would have to handle all 4 lamps plus both indicators?
     
  2. Nov 18, 2020
    oldtime

    oldtime oldtime

    St. Charles,...
    Joined:
    Aug 14, 2006
    Messages:
    3,478
    Flashers and indicators are normally fused at 14 amps.
    Use Buss or Littlefuse SFE 14.
    Fuse goes direct between the 550 flasher (12 volt) and the key switch “acc” terminal.
     