Proflo 4 Issue

Discussion in 'Intermediate CJ-5/6/7/8' started by CaseyF, Apr 16, 2021.

  1. Apr 16, 2021
    CaseyF

    CaseyF New Member

    North Texas
    Joined:
    Sep 29, 2020
    Messages:
    5
    Just completed my install of the PF4 on my 77 cj 304. When I connected to power my entire fuel line from my batt through my relay and all the way back to the tank heated and smoked all insulation off and melted the relay. Has anyone had this happen? Where do I start after dropping the tank and testing the pump? This is my first project so if its an obvious issue i may just still be ignorant.... (fuel pump is an in tank pump)
     
  2. Apr 16, 2021
    Jw60

    Jw60 Cool school 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Sedalia MO.
    Joined:
    Apr 8, 2008
    Messages:
    4,790
    I would say the wire got pinched and shorted to ground. Try again but add a fuse as close to the battery as possible.
     
    Fireball likes this.
  3. Apr 17, 2021
    CaseyF

    CaseyF New Member

    North Texas
    Joined:
    Sep 29, 2020
    Messages:
    5
    Thank you for the reply, I had the same thoughts but wasn’t sure if that would cause it. Will definitely go with the fuse suggestion as well.
     